4.4.1* General. Objects projecting from walls (for example, telephones) with their leading edges between 27 in. and 80 in. (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in. (100 mm) into walks, halls, corridors, passageways, or aisles (see Fig. 8(a)). Objects mounted with their leading edges at or below 27 in. (685 mm) above the finished floor may protrude any amount (see Fig. 8(a) and (b). Free-standing objects mounted on posts or pylons may overhang 12 in. (305 mm) maximum from 27 in. to 80 in. (685 mm to 2030 mm) above the ground or finished floor (see Fig. 8(c) and (d)). Protruding objects shall not reduce the clear width of an accessible route or maneuvering space (see Fig. 8(e)). Toll-Free ADA Information Line: (800) 514-0301 Clicking Here Takes You Offsite to: ADA Accessibility Guidelines
The diagram illustrates an area where an overhang can be greater than 12 inches (305 mm) because the object cannot be approached in the direction of the overhang.
The minimum clear width for continuous passage is 36 inches. Thirty two (32) inches is the minimum clear width for a maximum distance of 24 inches (610 mm). The maximum distance an object can protrude beyond a wing wall is 4 inches (100 mm).
|